 Process Temperature: Up to 400° F (204° C)
 Operating Pressure: Std. 3,000 psig (20.68 MPa)
 Turndown Ratio: (Based on Max. rated flow)
Low viscosity fluids 10:1 standard
Medium viscosity fluids 100:1
High viscosity fluids Up to 1000:1
 Calibration: Calibrated with either a 1cP or 100cP liquid at 50% of maximum rated flow.
 Repeatability: ±0.05% of rate
 Linearity: ±0.5% of rate over upper 80% of full span. With enhanced signal conditioning, Up to ±0.1% of rate over full turndown range
 Output:
Hall Effect Sensor: 5-24 VDC square-wave pulse depending on supply, 3-wire, FM Approved, intrinsically safe
Magnetic Pick-up Sensor: 10 mV to 10 V sine-wave pulse depending on flow rate, 2-wire, Explosion-proof optional
Signal Conditioners and Transmitters: Refer to individual product sheets
 Materials of Construction:
Body (Case) and Cover: 316 SS, standard Other materials available
Shafts: 316 SS, standard
Impellers: UHMWPE, standard, PPS or PTFE
O-Rings: Viton® or Teflon® standard
Other materials available
Bolts: Zinc-plated Grade 8 alloy steel
Other materials and plating available
|