 Input Signal Type: Magnetic pickup, * MCP pickup, Contact Closure, Pulse
 Input Frequency Range: 0.2 Hz to 4 KHz
 Signal Level: 10 mV rms to 30 VDC
 Power Supply: 8-30 VDC, 100-240 VAC. Reverse polarity protection
 Analog Output: 4-20mA, 1-5V. 24mA overflow condition
 Load Resistance: Max 650 Ohms at 24 VDC
 Accuracy: ±0.02% of full scale
 Temperature Drift: 40 ppm/Deg. C
 Pulse Output: 0-5V, * 0-10V, Open Collector, AC Square. Internal pull up 10 k Ohms Recommended minimum load resistance 50 k Ohms
 Pulse Scaling: Divide by 1,10,100 per flow unit of measure
 Hi/Lo Alarm: Relay (2A, 30Vdc), 0-5V, Open Collector (0.5A, 30V)
 Communications: RS232 port for configuration and diagnostics
 Operating Temperature: -40°to +185°F (-40°to +85°C)
 Humidity: 0-90% Non-Condensing
 Enclosure: Extruded Aluminum; DIN Rail Mount; Explosion-Proof
 Regulatory: CE Compliant
Note: * Requires 12-30 VDC Power Supply
|