 Display: 6 digit 0.7" (17.8mm) high LCD
 Display Update Rate: 0.25s
 Data Retention: 10 years data retention
 Pulse Output: Open collector output
 Transducer Supply: 8-24V dc field adjustable, Max. 50mA
 Relays: Max Power: 1250VA; Max Voltage: 250V ac, 30V dc; Max Current: 5 Amps
 Power Supply:
DC: 11.5-28.5V DC, 200mA typical current
AC: 95-135V AC or 190-260V AC
 Operating Temperature: 0 to 55ºC
 Approvals:
Electrical ETL (US) approved to UL508 and CSA
Interference CE Compliance.
Enclosures CENELEC, FM, CSA and SAA approved enclosures for hazardous areas
 Frequency Input:
Minimum: 0.25Hz on Rate, 0Hz on Total
Maximum: 10kHz (except 414H which is 8kHz)
Scaling Range 0.1000 to 50,000 or 0.1000 to 4,000 (414H)
 Analog Input (Model 414A):
Inputs: Isolated 4-20mA, 0-20mA & 0-10V
Current: 250 ohms
Voltage: 10K ohms
Accuracy: 0.075%
Span: 0.1000 to 50,000
Cut off Point: Programmable
Relationship: Linear, square root or programmable power between 0 and 9.99
 Field Enclosures IP65 (Nema 4X)
 Explosion proof Enclosures
|